Absolute Pressure:
Total pressure measured from zero.
Back to top

Absolute Temperature:
See Temperature, Absolute.
Back to top

Absorption:
The chemical process by which a hygroscopic desiccant, having a high affinity with water, melts and becomes a liquid by absorbing the condensed moisture.
Back to top

Actual Capacity:
Quantity of gas actually compressed and delivered to the discharge system at rated speed and under rated conditions. Also called Free Air Delivered (FAD).
Back to top

Adsorption:
The process by which a desiccant with a highly porous surface attracts and removes the moisture from compressed air. The desiccant is capable of being regenerated.
Back to top

Aftercooler:
A heat exchanger used for cooling air discharged from a compressor. Resulting condensate may be removed by a moisture separator following the aftercooler.
Back to top

Air Receiver:
See Receiver.
Back to top

Atmospheric Pressure:
The measured ambient pressure for a specific location and altitude.
Back to top

Automatic Sequencer:
A device which operates compressors in sequence according to a programmed schedule.
Back to top

Brake Horsepower (bhp):
Horsepower delivered to the output shaft of a motor or engine, or the horsepower required at the compressor shaft to perform work.
Back to top

Capacity:
The amount of air flow delivered under specific conditions, usually expressed in cubic feet per minute (cfm).
Back to top

Capacity, Actual:
The actual volume flow rate of air or gas compressed and delivered from a compressor running at its rated operating conditions of speed, pressure, and temperature. Actual capacity is generally expressed in actual cubic feet per minute (acfm) at conditions prevailing at the compressor inlet.
Back to top

Capacity Gauge:
A gauge that measures air flow as a percentage of capacity, used in rotary screw compressors as an estimator during modulation controls.
Back to top

Compression, Adiabatic:
Compression in which no heat is transferred to or from the gas during the compression process.
Back to top

Compression, Isothermal:
Compression in which the temperature of the gas remains constant.
Back to top

Compression Ratio:
The ratio of the absolute discharge pressure to the absolute inlet pressure.
Back to top

Constant Speed Control:
A system in which the compressor is run continuously and matches air supply to air demand by varying compressor load.
Back to top

Cubic Feet Per Minute (cfm):
Volumetric air flow rate.

Cfm, Free Air:
Cfm of air delivered to a certain point at a certain condition, converted back to ambient conditions.

Actual Cfm (acfm) :
Flow rate of air at a certain point at a certain condition at that point.

Inlet Cfm:
Cfm flowing through the compressor inlet filter or inlet valve under rated conditions.

Standard Cfm:
Flow of free air measured and converted to a standard set of reference conditions (14.5 psia, 68°F, and 0% relative humidity).
Back to top

Cut In/Cut Out Pressure:
Respectively, the minimum and maximum discharge pressures at which the compressor will switch from unload to load operation (cut in) or from load to unload (cut out).
Back to top

Cycle:
The series of steps that a compressor with unloading performs; 1) fully loaded, 2) modulating (for compressors with modulating control), 3) unloaded, 4) idle.
Back to top

Cycle Time:
Amount of time for a compressor to complete one cycle.
Back to top

Degree of Intercooling:
Difference in air or gas temperature between the outlet of the intercooler and the inlet of the compressor.
Back to top

Demand:
Flow of air at specific conditions required at a point or by the overall facility.
Back to top

DER:
Distributed Energy Resources.
Back to top

Desiccant:
A material having a large proportion of surface pores, capable of attracting and removing water vapor from the air.
Back to top

Desuperheat:
Reduce refrigerant gas temperature.
Back to top

Dew Point:
The temperature at which moisture in the air will begin to condense if the air is cooled at constant pressure. At this point the relative humidity is 100%.
Back to top

Discharge Pressure:
Air pressure produced at a particular point in the system under specific conditions.
Back to top

Discharge Temperature:
The temperature at the discharge flange of the compressor.
Back to top

Efficiency, Compression:
Ratio of theoretical power to power actually imparted to the air or gas delivered by the compressor.
Back to top

Efficiency, Isothermal:
Ratio of the theoretical work (as calculated on a isothermal basis) to the actual work transferred to a gas during compression.
Back to top

Efficiency, Mechanical:
Ratio of power imparted to the air or gas to brake horsepower (bhp).
Back to top

Efficiency, Volumetric:
Ratio of actual capacity to piston displacement.
Back to top

Enthalpy:
The internal temperature of a substance plus pressure time volume.
Back to top

Free Air:
Air at atmospheric conditions at any specified location, unaffected by the compressor.
Back to top

Full-Load:
Air compressor operation at full speed with a fully open inlet and discharge delivering maximum air flow.
Back to top

Gauge Pressure:
The pressure determined by most instruments and gauges, usually expressed in psig. Barometric pressure must be considered to obtain true or absolute pressure.
Back to top

GW:
Gigawatt - One billion watts.
Back to top

Horsepower, Brake:
See Brake Horsepower.
Back to top

Horsepower, Theoretical or Ideal:
The horsepower required to isothermally compress the air or gas delivered by the compressor at specified conditions.
Back to top

Humidity, Relative:
The relative humidity of a gas (or air) vapor mixture is the ratio of the partial pressure of the vapor to the vapor saturation pressure at the dry bulb temperature of the mixture.
Back to top

Humidity, Specific:
The weight of water vapor in an air vapor mixture per pound of dry air.
Back to top

Hz:
Hertz - A unit of frequency equal to one cycle per second.
Back to top

Indicated Power:
Power as calculated from compressor-indicator diagrams.
Back to top

Inlet Pressure:
The actual pressure at the inlet flange of the compressor.
Back to top

Intercooling:
The removal of heat from air or gas between compressor stages.
Back to top

Isentropic:
Without change in measure of the systems capacity to undergo change.
Back to top

kW:
Kilowatt - A unit of power equal to 1000 watts.
Back to top

kWh:
Kilowatt hour - A unit of energy equal to 1000 watts operating for one hour.
Back to top

Leak:
An unintended loss of compressed air to ambient conditions.
Back to top

LHV:
Lower Heating Value = 900 - 950 Btu/scf.
Back to top

Load Factor:
Ratio of average compressor load to the maximum rated compressor load over a given period of time.
Back to top

Load Time:
Time period from when a compressor loads until it unloads.
Back to top

Load-Unload Control:
Control method that allows the compressor to run at full-load or at no load while the driver remains at a constant speed.
Back to top

Modulating Control:
System which adapts to varying demand by throttling the compressor inlet proportionally to the demand.
Back to top

MW:
Megawatt - One million watts.
Back to top

Perfect Intercooling:
The condition when the temperature of air leaving the intercooler equals the temperature of air at the compressor intake.
Back to top

Piston Displacement:
The volume swept by the piston; for multistage compressors, the piston displacement of the first stage is the overall piston displacement of the entire unit.
Back to top

Pneumatic Tools:
Tools that operate by air pressure.
Back to top

Pressure:
Force per unit area, measured in pounds per square inch (psi).
Back to top

Pressure Dew Point:
For a given pressure, the temperature at which water will begin to condense out of air.
Back to top

Pressure Drop:
Loss of pressure in a compressed air system or component due to friction or restriction.
Back to top

Pressure Range:
Difference between minimum and maximum pressures for an air compressor. Also called cut in-cut out or load-no load pressure range.
Back to top

Rated Capacity:
Volume rate of air flow at rated pressure at a specific point.
Back to top

Rated Pressure:
The operating pressure at which compressor performance is measured.
Back to top

Receiver:
A vessel or tank used for storage of gas under pressure. In a large compressed air system there may be primary and secondary receivers.
Back to top

Relative Humidity:
The ratio of the partial pressure of a vapor to the vapor saturation pressure at the dry bulb temperature of a mixture.
Back to top

Required Capacity:
Cubic feet per minute (cfm) of air required at the inlet to the distribution system.
Back to top

Saturation Temperature:
For a fluid, the boiling point corresponding to a given pressure.
Back to top

Sequence:
The order in which compressors are brought online.
Back to top

Specific Humidity:
The weight of water vapor in an air-vapor mixture per pound of dry air.
Back to top

Specific Power:
A measure of air compressor efficiency, usually in the form of bhp/100 acfm or acfm/bhp.
Back to top

Specific Weight:
Weight of air or gas per unit volume.
Back to top

Standard Air:
The Compressed Air & Gas Institute and PNEUROP have adopted the definition used inISO standards. This is air at 14.5 psia (1 bar); 68°F (20°C) and dry (0% relative humidity).
Back to top

Start/Stop Control:
A system in which air supply is matched to demand by the starting and stopping of the unit.
Back to top

Superheat:
Temperature of refrigerant gas.
Back to top

Surge:
A phenomenon in centrifugal compressors where a reduced flow rate results in a flow reversal and unstable operation.
Back to top

Temperature, Absolute:
The temperature of air or gas measured from absolute zero. It is the Fahrenheit temperature plus 459.6 and is known as the Rankine temperature. In the metric system, the absolute temperature is the Centigrade temperature plus 273 and is known as the Kelvin temperature.
Back to top

Temperature, Discharge:
The total temperature at the discharge connection of the compressor.
Back to top

Temperature, Inlet:
The total temperature at the inlet connection of the compressor.
Back to top

Temperature Rise Ratio:
The ratio of the computed isentropic temperature rise to the measured total temperature rise during compression. For a perfect gas, this is equal to the ratio of the isentropic enthalpy rise to the actual enthalpy rise.
Back to top

Temperature, Static:
The actual temperature of a moving gas stream. It is the temperature indicated by a thermometer moving in the stream and at the same velocity.
Back to top

Temperature, Total:
The temperature which would be measured at the stagnation point if a gas stream were stopped, with adiabatic compression from the flow condition to the stagnation pressure.
Back to top

Theoretical Power:
The power required to compress a gas isothermally through a specified range of pressures.
Back to top

Torque:
A torsional moment or couple. This term typically refers to the driving couple of a machine or motor.
Back to top

Total Package Input Power:
The total electrical power input to a compressor, including drive motor, cooling fan, motors, controls, etc.
Back to top

Unload:
(No load) Compressor operation in which no air is delivered due to the intake being closed or modified not to allow inlet air to be trapped.
Back to top

Watt:
A unit of power equal to 3.413 Btu/hour.
Back to top